Voltage Monitoring Relays
Frequency Monitoring Relays
Power Monitoring Relays & CBCT
Level Controllers – Conductive Liquids
Level Controllers – Non Conductive Liquids

Alarm Annunciators

MBAS 0600/MICRO 17

MBAS 0600 is a improved version of earlier MBAS 9400, and is available for 4 to 40 windows

    The Functional Features
  • Fixed Sequence ( S1/S2/S3/S4)
  • Potential free dry contact inputs
  • NO/NC inputs selectable configuration
  • Relay output for external Audible Hooter 3rd Relay optional for either of below mentioned features
    a) Ring back hooter
    b) Supervisory control
  • Minilec Standard Communication Protocol
    The Design Features
  • Single chip microcontroller logic
  • Opto isolated inputs and outputs
  • Super Bright LED window illumination
  • High Noise immunity / isolation
  • Switch mode power supply
  • Self surveillance watchdog LED
    The Constructional Flexibility
  • Conforming to DIN panel cutouts
  • Replaceable snap-on window capsules
  • Two different window size
  • Molded enclosures
    Optional Features
  • Any custom built operating sequences
  • Manned / Unmanned function
  • MODBUS RTU/ASCII Protocol
  • Fault Follower contact output per fault Input (NO or NC)
  • Supply fail indication / annunciation Built in
  • Built-in control push buttons
Timing/ Relay logic Diagram
Back view showing Terminal details
PC Side software
The MBAS 0600 annunciation systems is configured in multiples of four basic ABS moulded enclosures
  • Supply Voltage 24 / 30 / 48 / V DC, 20-60 V AC/DC, 90-270 V AC / DC
  • Windows4 / 6 / 8 / 12 / 16 / 18 / 22 / 24 / 32
  • Window Sizes30 x 30mm / 30 x 65 mm
  • Display DeviceSuper bright high efficiency low power consuming LED's
  • Facia Type Individual windows Front Replaceable
  • Window/LED ColoursRED, Yellow, Green, White & Blue
  • Flash RateFast - 60 flashes/min. Slow - 30 flashes/min.
  • Response Time40 msec.
  • Input SignalPotential free contacts (NO or NC site selectable)
  • GroupingTrip / Non Trip site selectable
  • Interrogation Voltage + 12 V DC
  • Output Contacts 1 NO + 1 NO + 1 NO (optional)
  • Architecture Integrated
  • Operational Sequences
    (site selectable)
    Auto/Manual/First-up/Ringback (optional) OR any other sequence on request
  • Operational Temp0-60 degrees C
  • Power Consumption1.5 Watts per Window (Max)
  • OptionalAC-DC fail Annunciation or Indication / Repeat Relays / RS232 - 485 Port
    Dimensions (mm)
  • Panel Cutout (L x W)
    Overall (L x W x D)
    1D
    138 x 68
    144 x 72 x 215
    2D
    138 x 138
    144 x 144 x 215
    3D
    138 x 210
    144 x 216 x 215
    4D
    138 x 282
    144 x 288 x 215
    Wherever not specified Contact Rating : 5A @ 230 V AC (resistive) * CE marked products available on request.
    Note:
  • In Case of Normal Supply Failure, RLY-3 is for Stand by Hooter (at AC/DC fail feature)
  • For supply fail Annunciators/Indication, Window no. 01 is dedicated
  • External SMPS is provided for different supply voltages
Part names & locations
Dimnesional & Panel Cutout Details
    Note:
  • In Case of Normal Supply Failure, RLY-3 is for Stand by Hooter (at AC/DC fail feature)
  • For supply fail Annunciators/Indication, Window no. 01 is dedicated.
  • External SMPS is provided for different supply voltages.

Suitable for Panels in Following Apllications :

  • Suitable for Process
  • Plants, Diesel Generators
  • Control Rooms
  • C & R Panel
  • Material handling Systems
  • Instrumentation Panel
  • Battery Charger panel
  • Compressor control panel